SM 15-200 D P127
SM 30-100 D P128
SM 45-70 D P129
SM 70-45 D P130
SM 3000 with Power Sink Option
2 Quadrant operation: Source and Sink
SM45-70D with Power Sink Op tion
Cur rent –10 A means the load de liv ers 10 A to
the power sup ply (sink op er a tion)
Up per trace: out put volt age
Lower trace: out put cur rent
(cur rent switch ing from +40 A to –10 A at Vo=15 V)
SM45-70D with out Power Sink Op tion
The out put volt age is out of con trol when
the out put cur rent is neg a tive
Up per trace: out put volt age
Lower trace: out put cur rent
(cur rent switch ing from +40 A to –10 A at Vo=15 V)
The Power Sink option permits the power supply to absorb
bursts of power fed back to the unit. An internal module senses
the status of power supply and sinks current across the output
terminals, thus maintaining a constant output voltage.
The Power Sink Option allows a faster response when the
power supply is step programmed to a lower voltage at small
load conditions.
Can absorb 300 W peak power
Maintains output voltage setting regardless output power
is positive or negative (source and sink)
Ideal solution for supplying electric motors with
PWM-speed control. These systems often return power to
the power supply during a braking action
Ideal solution for ATE systems requiring fast down
programming at no load conditions
Generation Automotive waveforms (fast)
U
nit 8A
Arnhem Road
Newbury. RG14 5RU
T
el: +44 (0) 1635 521858
Fax: +44 (0) 1635 523771
www.powersolve.co.uk
Models Order Code:
Zobrazit stránku 0
1 2

Shrnutí obsahu

Strany 1 - Models Order Code:

SM 15-200 D P127SM 30-100 D P128SM 45-70 D P129SM 70-45 D P130SM 3000 with Power Sink Option 2 Quadrant operation: Source and SinkSM45-70D with Power

Strany 2 - SM3000 - P127- P130

SM3000 - P127- P130Page 1 - 2 Datasheet - SM3000 Power Sink 2003, rev. Sep.2011SM45-70D with Power Sink Op tionfast dis charge of out put ca pac i

Komentáře k této Příručce

Žádné komentáře