SPECIFICATIONS Preliminary version Power Sink SM3300
Page 1 - 2 February 2013, Preliminary version
Power Sink Spec i fi ca tions
SM18-220
Option P306
SM66-AR-110
Option P308
SM100-AR-75
Option P309
SM330-AR-22
Option P310
SM660-AR-11
Option P311
Sink Power Rat ing
max. peak power (elec tron i cally lim ited)
max. continuous power (T
amb
. = 25 °C)
max. continuous power (T
amb
. = 50 °C)
300W
300W
t.b.d
Max. du ra tion Sink Peak Power
P
sink
=P
max
, T
amb
. = 25 °C
Duty Cy cle for use at Peak Power
P
sink
=P
max
, T
amb
. = 25 °C
con tin u ous @ P
sink
= 300 W
100% @ P
sink
= 300 W
Max. Sink Cur rent
(V
o
>= 2 V and P <= P
max
)
Lim ited at
75 A
Lim ited at
75 A
Lim ited at
75 A
Lim ited at
10 A
Lim ited at
10 A
Pro tec tion
Elec tronic Power Limit lim its the cur rent.
The tem per a ture of the power sink is fan con trolled and
the cir cuit shuts down in case of ther mal over load.
Re cov ery time / De vi a tion
Vo = 6 V, I
o
: +100 A –30 A
re cov ery within 100 mV / de vi a tion:
Vo = 15 V, I
o
: +100 A –10 A
re cov ery within 100 mV / de vi a tion:
Vo = 24 V, I
o
: +70 A –7.5 A
re cov ery within 100 mV / de vi a tion:
Vo = 60 V, I
o
: +35 A –3 A
re cov ery within 100 mV / de vi a tion:
Vo = 300 V, I
o
: +8 A –0.5 A
re cov ery within 1 V / de vi a tion:
Vo = 600 V, I
o
: +4 A –0.25 A
re cov ery within 1 V / de vi a tion:
(load cur rent switches from pos i tive
to neg a tive)
di/dt = – 2.5A/µs
400 µs / 0.30 V
di/dt = – 2.5A/µs
450 µs / 0.30 V
-
-
-
-
note: val ues
are typ i cal
di/dt = – 2.5A/µs
750 µs / 1.20 V
di/dt = – 2.5A/µs
600 µs / 0.85 V
di/dt = – 1.5A/µs
1.1 ms/ 0.90 V
di/dt = – 1.0A/µs
2.0 ms/ 0.90 V
-
-
note: val ues
are typ i cal
-
-
di/dt = –1.8A/µs
600 µs / 0.65 V
di/dt = – 0.8A/µs
2.2 ms/ 0.60 V
-
-
note: val ues
are typ i cal
-
-
-
-
di/dt = – 0.3A/µs
1.0 ms/ 1.9 V
-
note: val ues
are typ i cal
-
-
-
-
di/dt = – 0.15A/µs
0.5 ms/3.0 V
di/dt = – 0.07A/µs
1.5 ms/ 3.0 V
note: val ues
are typ i cal
Pro gram ming Down Speed
Fall time at no load (90 - 10%)
Fall time at no load with out Power Sink
Fall time at no load (90 - 10%)
Fall time at no load with out Power Sink
Unit with Fast Pro gram ming Op tion
Fall time at no load (90 - 10%)
Fall time at no load with out Power Sink
Fall time at no load (90 - 10%)
Fall time at no load with out Power Sink
(6 0 V)
2.3 ms
1.2 s
(18 0 V)
14.8ms
4.2 s
P306+P300
(6 0 V)
0.09ms
23ms
(18 0 V)
0.3ms
34ms
(33 0 V)
5.6ms
3.5 s
(66 0 V)
23ms
5.0 s
P308+P302
(33 0 V)
0.55 ms
150ms
(66 0 V)
1.5ms
600ms
(50 0 V)
11 .5ms
2 .3 s
(100 0 V)
45.0ms
9.4 s
P309+P303
(50 0 V)
0.48ms
60.6ms
(100 0 V)
1.4ms
425ms
(165 0 V)
14 ms
3.5 s
(330 0 V)
50 ms
12 s
P310+P304
(165 0 V)
1.5 ms
600 m s
(330 0 V)
4.8 ms
2 s
(330 0 V)
12 ms
3.5 s
(660 0 V)
45 ms
11 s
P311+P305
(330 0 V)
2.2 ms
720 ms
(660 0 V)
8 ms
3.8 s
Par al lel and Se ries op er a tion
Re fer to power sink man ual for
de tails and re stric tions.
Us ing mul ti ple units in par al lel op er a tion, only one unit can have a power sink .
Us ing mul ti ple units in se ries op er a tion, all units must have a power sink .
SM66-AR-110 with Power Sink Op tion
fast dis charge of out put ca pac i tors
by Power Sink circuit
Trace: out put volt age
Volt age Pro gram ming Speed at NO LOAD
SM66-AR-110 with out Power Sink Op tion
slow re sponse time dur ing volt age step down,
time needed to dis charge the out put ca pac i tors
Trace: out put volt age
Volt age Pro gram ming Speed at NO LOAD
The maximum sink current at higher voltages will not be the maximum specified current due to the power limit.
For example for an SM66-AR-110 at 30V, the max sink current will be 10 A (30 V x 10 A = 300 W = max power).
A higher sink current than the maximum current will cause the output voltage to rise.
Notes: